Symptoms:

  • Shift concerns associated with circuit pressure loss

Cause:

Valves, springs and fluid pressure push on the end plugs, eventually causing distortion and excessive clearance between the end plug and bore.

Correction:

These Sonnax end plugs with O-rings restore hydraulic circuit integrity.

09D, 09G, 09K, 09M, 6F21WA, TF-60SN, TF-80SC, TF-81SC, TR-60SN

O-Ringed End Plug Kit
Part No. 15741-36K

You need this if... View Instructions

Sonnax O-ringed end plug kit 15741-36K will fit many of the 11mm diameter bores in the listed units that have OE end plugs of similar configuration. The Sonnax end plugs feature an additional groove for the O-ring, but otherwise are similar to the OE end plugs in design and retention method. Compare your OE end plug to detail image and see if the design is similar.

For 9mm diameter bores in listed applications, Sonnax offers 15741-35K.

  • End Plugs (5) 11mm
  • O-Rings (7) Small

Sonnax valve body layouts provide a detailed overview of individual units making it quick and easy to determine what’s available for the specific valve body you’re working on. See all Sonnax valve body layouts.

Aisin AW TF-80SC Valve Body Layout

Tf 80sc vbl thumb

Aisin AW TF-81SC Valve Body Layout

Tf 81sc vbl thumb

Aisin AW TR-60SN Valve Body Layout

Tr 60sn vbl thumb

Aisin AW TF-60SN Valve Body Layout

Tf 60sn vbl thumb

October 16, 2014

Aisin AW TF-60SN, BMW 6F21WA, VW/Audi 09G, 09K, 09M Vacuum Test Guide

Topics: Vacuum Test Guides Vacuum Testing Transmission BMW VW/Audi Aisin AW 6F21WA Transmission 09G, 09K, 09M Transmission TF-60SN Transmission

Read Now
  • 15741 36k alt4 alt
  • 15741 36k alt
  • 15741 36k alt2 alt
  • 15741 36k alt3 alt
  • 15741 36k

You need this if...

A vacuum test at the retainer cavity will not hold 17" of vacuum.