Published 03-2009, by Ed Lee
Sometimes misunderstood, and often overlooked,
but very important!
"Internal clearance" is the space between the
impeller and the turbine in an assembled
torque converter (Figure 1).
Hydraulically, it is the distance that the oil
travels from where it exits the vanes of the
impeller to where it enters the vanes of the
turbine. Some rebuilders use the term
"internal clearance" incorrectly. They use it to
refer to the clearance between the internally
stacked components of the converter. The
correct term for the clearance between the
stacked components is "end play".
In a perfect world, the converter would operate at its maximum efficiency when the impeller and turbine are as close as possible, without touching. In the real world, where nothing is perfectly straight or true, some extra clearance is necessary to prevent contact between the moving parts. This extra clearance also builds in some planned inefficiency, which allows the transmission to remain in gear without stalling the engine when the vehicle is stopped. Most 10" to 12" diameter converters will operate efficiently with about .080" to .100" of internal clearance. Larger converters need a little more clearance to keep the parts from touching.
Minimizing the internal clearance of a torque converter has been an effective method of lowering the stall and increasing the efficiency on converters coupled to diesel and long stroke gas power plants. This method has been used on the Cummins diesel converters for many years. Increasing the internal clearance to more than the OE specification will have the opposite effect. It will raise the stall and decrease the efficiency of the converter. Increasing internal clearance is the least desirable method of increasing stall. The July 2007 Transmission Digest article "Myth Busters Part #3" illustrated how small changes in stall and large changes in generated heat were caused by increasing the internal clearance in the Chrysler 518 converter in a test vehicle from .080" to .160". The increase in internal clearance was the only change made to the vehicle, and the transmission overheated during the two and a half minute dyno test. The greater the gap between the impeller and turbine, the greater the oil sheer and the more heat generated.
There are some very obvious and some not so obvious by-products of having too much internal clearance.
One Very Obvious Example
A racer was converting an ex pro stock car
into a super pro car. He was using a 540 c.i.
big block Ford engine with a Powerglide
transmission and an 8" converter. The
transmission was equipped with three three
temperature probes connected to a digital
read out. One probe was in the pan, one was
in the cooler line where the oil exited the
transmission, and the other was in the return
cooler line. The temperature probe where the
oil exits the transmission is the first place the
oil goes when it leaves the converter. At the
starting line, this probe was already reading
190°F. By the end of the quarter mile, the
temperature was reading 308°F. The racer
did not need to see the temperature readings
to know that he had a problem, because the
paint on the converter already looked burnt
by the end of the first run. By the third run, the
temperatures were reading as high as 350°F
and the converter was starting to fail. The
converter was returned to the shop where it
was purchased, and the owner of the shop
insisted that the converter was built properly
and the racer must have abused it. Over the
next several weeks, the racer changed the
cooler and even installed a completely
different transmission, but always got the
same results. The transmission would run
hot and the converter would only last three or four
runs. The racer eventually replaced the
converter and the problem went away.
Comparing the two converters, the only
significant difference was the internal
clearance. The converter that worked
successfully had an internal clearance
between .090" and .100" and the problem
converter had an internal clearance that
exceeded .160".
The difference in performance between the converters was dramatic. The quarter-mile elapsed time went from 8.58 sec. to 8.40 sec. with the new converter. The 60' times went from 1.234 sec. to 1.185 sec. and the speed went from 159 mph to 161.40 mph. The finish line temperature on the new converter was about 100 to 120 degrees cooler than the old converter. However, the biggest difference was that the racer was making 125 runs between cleanouts on the converter. The new converter never failed and looked so good at the time of the cleanouts that the racer got as many as 215 runs on the converter at one point.
A Not So Obvious Example
A torque converter rebuilder started to notice
a higher than normal comeback rate on one of
his Ford converters. The converters were
coming back wiped out and the Bakelite stator
caps were coming out looking like small black
marbles. The fluid smelled like 90-weight gear
lube and the paint on the converters was
burnt, so he knew that the converters were
overheating. At first he blamed the customers,
but too many were having the same problem.
At one point a converter came back with the
paint burnt, but the converter had not yet self
destructed. When the shop cut the converter
open, the only thing they found out
of the ordinary, was small blisters on the side
of the stator cap.
The shop owner reasoned that the stator caps
were not standing up to the heat, and they were
causing the converters to fail. The only flaw in
his theory was that his friend (also a torque
converter rebuilder) was using the same stator
caps and was not having any problems. He
asked his friend to check his rebuild
procedure, to make certain that he was not
doing anything wrong. The friend found that
the converter had too much internal clearance
and explained that the excessive internal
clearance was probably causing the converters
to overheat. At first the rebuilder thought that
his friend was talking about the converter's end
play. When the friend explained what he
meant by "internal clearance", the rebuilder
said that in his 30-plus years of rebuilding
torque converters, he had never checked the
internal clearance and did not believe that it
could cause the problem. He reluctantly
agreed to check and adjust his converter's
internal clearance for a short period of time.
Since that time his comeback rate on the Ford
converters has returned to normal and a
couple of other problems that had not
been recognized also went away. Checking
and adjusting the converter's internal clearance
has become an important part of his
rebuild procedure.
FYI
The stator cap in Figure 2 was in a low mileage rebuilt GM converter that was returned to a builder because of a transmission related problem. The blistering on the side of the stator cap was the result of .245" of internal clearance. This converter would have failed prematurely because of the incorrect internal clearance.
Checking Internal Clearance
Put the impeller on a flat surface and place the turbine (with turbine hub) right on top of the impeller, so the veins are in contact. In that position, there is no clearance between the impeller and turbine. Measure from the top of the turbine hub down to the flat surface and record your measurement (Figure 3).
Now, take the turbine out of the impeller and place the stator and all thrust components into the impeller, followed by the turbine. The impeller and turbine are now separated by the stator and thrust washer. Once again, measure from the top of the turbine hub down to the flat surface. The difference between the two measurements is the internal clearance.
Ed Lee is a Sonnax Technical Specialist who writes on issues of interest to torque converter rebuilders.
Sonnax supports the Torque Converter Rebuilders Association. Learn more about the group at www.tcraonline.com.
Sonnax Industries is an Employee-Owned Company
1 Automatic Drive · Bellows Falls, VT ·
05101-0440 · U.S.A.
800-843-2600 ·
802-463-9722
Sonnax Industries is an ISO 9001: 2008 Registered Company
© 2012 Sonnax Industries, Inc.