Published 02-2009, by Ed Lee
A 2003 F350 4X4 was brought to a
transmission shop in Eugene, Oregon. The
customer complaint was an intermittent
P0741 code. The code did not seem to occur
when the vehicle was driven locally, but
happened every time the vehicle was taken on
a longer trip. The customer also noticed that
the code would set whenever any additional
load was placed on the vehicle. The
additional loads included traveling in hilly
terrain or pulling a trailer. The vehicle's
transmission had been rebuilt at the same
transmission shop about a year earlier and a
rebuilt torque converter had been installed at
that time. During the transmission rebuild
procedure a few mild performance enhancing
modifications were added, but other than
that, it was a basic overhaul. The customer
said that the lock-up worked fine for about
300 miles, but then complained that the
lock-up was too soft. The soft lock-up feel
continued until the present P0741 code issue.
A scan check did not find any additional
codes and a road test with the scanner showed
that there was sufficient TCC slip to set the
code. All of the routine "in vehicle" checks
were performed and the cause of the problem
was believed to be the converter.

The transmission shop had changed hands during the past year, but the new owner was familiar with the customer and was willing to stand by the warranty. The transmission and converter were removed from the vehicle. The new shop owner had changed his torque converter supplier since acquiring the shop, so the torque converter did not go back to the original rebuilder. The converter was sent to the shop's new supplier, Oregon Converter Company. Ken Cluck, the production manager at Oregon Converters, had the converter cut apart. The end play and clutch release clearances were within specifications, and the clutch did not look like it had been slipping. Ken was convinced that the TCC slip problem was originating outside of the converter, but as an extra measure of insurance, a new clutch piston was installed.
The transmission and converter were put back into the vehicle and the vehicle was road tested. The extensive road test covered all types of terrain, including several hilly areas. Since the TCC slip condition did not return during the road test, Ken felt that the problem had been resolved, even though he had not found anything conclusive inside the converter.
The vehicle was returned to the customer and once again, it performed well for about 300 miles. After 300 miles the TCC apply feel again began to soften. By the time the vehicle was returned to the transmission shop, the data stream was showing enough TCC slip that the return of the P0741 code was inevitable. Since the converter reacted in much the same way as it did after the first rebuild, Ken felt he needed to take a closer look.
The Answer
Closer scrutiny of the converter did reveal something that was missed on the first inspection. The bushing in the I.D. bore of the TCC piston looked like new, but there seemed to be more than normal clearance between the bushing and turbine hub. The OE clearance for this area, when the converter is new, is about .0015" to .002". There is a general rule of inspection for a unit that has been in the field. If a .002" feeler gauge fits between the bushing in the TCC piston and the turbine hub, the bushing is good. If a .003" feeler gauge is a tight fit, the bushing is marginal, but will work. If a .004" or larger feeler gauge will fit, the bushing must be replaced. Ken found that he could fit a .007" feeler gauge between the bushing and turbine hub on the problem converter (Figure 1).
Since there is no additional O-ring or
lathe cut seal located between the
piston and turbine hub, the clearance
between the bushing and turbine hub
acts as an orifice. Almost five times as
much oil was leaking past this area than
there should have been, because of the
excess clearance. Ken went back and
checked the piston he had replaced the
first time around. He found that an
.011" feeler gauge would fit between the
piston bushing and turbine hub. This extra
clearance with either piston would explain
the P0741 code, but why was the
clearance there?

The Answer To The Answer
When the Oregon Converter Company rebuilt the converter, they reused the turbine hub, which looked like new. The turbine hub had been replaced by the original rebuilder. Unfortunately, the surface finish on the turbine hub, where the bushing in the I.D. of the TCC piston rides, was rough enough to wear the bushing out prematurely. The surface finish for this area should be in the 10 to 20 RA range. The surface finish on this turbine hub exceeded the profilometer's maximum reading of 200 RA, and a good guess would put this turbine hub's finish at about 300 RA. The finish was rough enough to catch a fingernail but was difficult to detect visually. In fact, the O.D. of the problem turbine hub measured the same as an OE hub, and felt smooth when you ran your finger around the circumference. If you do not have a profilometer, the best method of checking for smoothness is to run your fingernail across the surface, or place your pocket screwdriver at a 45 degree angle to the surface and push it across the surface (Figure 2).
Most converters rely on an O-ring or lathe cut seal to control oil flow between the turbine hub and TCC piston. Because the 4R100 or 5R110W converters do not have any seal in this area, it becomes critical that this clearance be measured during the rebuild process.
Special thanks to Ken Cluck, Production
Manager at Oregon Converters for sharing his
story and information.
Ed Lee is a Sonnax Technical Specialist who
writes on issues of interest to torque converter
rebuilders.
Sonnax supports the Torque Converter
Rebuilders Association. Learn more about the
group at www.tcraonline.com.
Sonnax Industries is an Employee-Owned Company
1 Automatic Drive · Bellows Falls, VT ·
05101-0440 · U.S.A.
800-843-2600 ·
802-463-9722
Sonnax Industries is an ISO 9001: 2008 Registered Company
© 2012 Sonnax Industries, Inc.