January 01, 2013
ZF6HP26 Solenoid Identification
Valve Body Xpress
Please remove your original TCM and keep it in a safe place. Do not send it in with your valve body for R&R. Read about Electrostatic Discharge before servicing this valve body.
The TCM is not included.
January 01, 2013
Valve Body Xpress
April 11, 2016
This valve body is available to distributors through the R&R service only.
Learn MoreName |
Type |
Resistance (at 68°F) |
Connector Color |
Function |
---|---|---|---|---|
MV1 |
On/Off |
10-10.5 Ohms |
Black |
Moves a valve to allow EDS4 to control clutch E |
MV2 |
On/Off | 10-10.5 Ohms | Black |
Park |
MV3 |
On/Off | 24-26 Ohms | Green |
Park |
EDS1 |
Normally Vented |
5 Ohms |
Yellow |
Clutch A |
EDS2 |
Normally Applied |
5 Ohms | Blue |
Clutch B |
EDS3 |
Normally Vented | 5 Ohms | Yellow |
Clutch C |
EDS4 |
Normally Applied |
5 Ohms | Blue |
Clutch D/E |
EDS5 |
Normally Applied | 5 Ohms | Blue |
EPC |
EDS6 |
Normally Vented | 5 Ohms | Yellow |
TCC |
Name |
Type |
Resistance (at 68°F) |
Connector Color |
Function |
---|---|---|---|---|
MV1 |
On/Off |
10-10.5 Ohms |
Black |
Moves a valve to allow EDS4 to control clutch E |
EDS1 |
Normally Vented |
5 Ohms |
Yellow |
Clutch A |
EDS2 |
Normally Vented | 5 Ohms | Blue |
Clutch B |
EDS3 |
Normally Vented | 5 Ohms | Yellow |
Clutch C |
EDS4 |
Normally Vented | 5 Ohms | Blue |
Clutch D/E |
EDS5 |
Normally Vented | 5 Ohms | Blue |
EPC |
EDS6 |
Normally Vented | 5 Ohms | Yellow |
TCC |