Symptoms:

  • Harsh shifts
  • Soft shifts
  • Solenoid performance codes

Cause:

Bore wear can cause excess leakage in the actuator feed limit circuit which can affect solenoid function resulting in various drivability issues.

Correction:

Restore hydraulic control by reconditioning the bore and installing Sonnax oversized actuator feed accumulator piston kit.

6T70 (Gen. 2), 6T75 (Gen. 2), 6T80 (Gen. 2)

Oversized Actuator Feed Accumulator Piston Kit
Part No. 124740-65K


You need this if... View Instructions Find a Distributor

GM Gen. 2 6T70/75/80 units often suffer shift abnormalities caused by excess wear in the actuator feed accumulator piston bores. This wear allows actuator feed limit fluid loss which prevents proper regulation of oil pressure supplied to control solenoids, resulting in harsh or soft shifts, solenoid codes and clutch failure.

Reconditioning the bore and installing Sonnax oversized actuator feed accumulator piston kit 124740-65K re-establishes correct clearance for revived shift control in all ranges.

  • Hardcoat anodized aluminum valve combats premature wear
  • Springs calibrated to match OE function

Original release 124740-TL40 works in Gen. 1 only. To update to work in Gen. 2 applications requires purchase of jig plate 124740-JP40.

  • Accumulator Pistons (6)
  • Springs (6)
  • 6T70 (Gen. 2), 6T75 (Gen. 2), 6T80 (Gen. 2) Oversized Actuator Feed Accumulator Piston Kit 124740-65K
  • 6T70 (Gen. 2), 6T75 (Gen. 2), 6T80 (Gen. 2) Oversized Actuator Feed Accumulator Piston Kit 124740-65K

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.