Symptoms:

  • 3-4 Flare
  • C2 Clutch burned
  • 4-5-6 Slip

Cause:

Wear at the C2 apply control valve can cause improper function of the C2 clutch.

Correction:

Reconditioning the bore and installing the Sonnax oversized C2 apply control valve kit will restore proper function of the C2 apply control valve, restoring proper clutch function.

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.

U660E, U660F, U760E, U760F Oversized C2 Apply Control Valve Kit Vacuum Test Locations